This is a metal pipe that attaches to the pellet stove at one end typically with a pellet stove pipe chimney adapter and extends all the way through the chimney and above the roof at a suitable clearance.
Installing chimney liner for pellet stove.
Proceed to lower the liner down the chimney until you reach the thimble.
When installing a chimney liner for a pellet stove there is one thing to remember.
This video shows the installation of a stove as well as the initial preparation testing and also re lining of an existing chimney using schiedel s tecnofle.
A liner going to an insert or stove in the fireplace will be measured from the top of the chimney to the top of the insert or stove or the center of the hole on the back of the stove.
If the chimney length is greater than 15 feet you should just up to a 4 inch chimney liner.
For wood pellet gas oil and coal burning appliances.
The vent cap must have a cover to prevent rain water from entering the vent and chimney liner.
Installing a pellet stove pipe in an existing chimney requires a chimney liner.
In this case you will need to go from the 4 inch chimney liner tee down to 3 inch.
Most pellet stoves have 3 inch vent sizes.
Twisting the flexible liner will help you install the liner if you are getting caught or hung up on the chimney walls.
A thick tarry smoke rises from every fire you burn and without a liner it will stick to the walls of your chimney and create a fire hazard.
Please remember these liners are sold in 5 increments 15 20 25 so for instance an 18 chimney will need a 20 liner.
The liner extends past the top of the chimney by at least a foot and is covered with a vent cap.